Profilecontact
All Types Of Cooling Towers MFG. Piping Air Conditioning Jobs Supply, Service And Maintenance
HOME
PROFILE
PRODUCTS
SERVICES
ENQUIRY
CONTACT
rolex replica
omega replica
replica breitling

























 

 

Products

Cooling Tower fabricators makes it quick and easy to find the parts you need for your cooling tower.

If at any time you would like to speak with one of our knowledgeable service representatives, or if you require an official bid, please call us. Our goal is to provide you with the information necessary to ensure you get the right parts every time you order.

Our Spares :

Cooling tower motors

SPECIFICATIONS

Frames: 71 to 225M.
Rating: 0.37 to 18.5 kW.
Poles: 4, 6, 8, 10 & 12
Mountings: B3, B5
Protection: IP55
Enclosure: Totally Enclosed (TE)

Fan and parts

FRP fans

Performance & Operating Ranges

Fan Diameter :300 mm to 10360 mm (1 ft. to 34 ft.)
No. of Blades : 2 to 12
Air Flow : 2 to 700 m3/sec
Pressure : 40 to 1600 Pa
Speed : 0 to 2500 RPM
Power Rating : 1 to 1000 kW
Operating Temp. : -20OC to +120O C

Aluminium fans

Performance & Operating Ranges

Fan Diameter :300 mm to 3657 mm (1 ft. to12 ft.)
No. of Blades : 2 to 12
Air Flow : 2 to 700 m3/sec
Pressure : 40 to 1600 Pa
Speed : 0 to 2500 RPM
Power Rating : 1 to 1000 kW
Operating Temp. : -20OC to +120O C

Gear Boxes

Different ratios
Individual gears
Gear Oil for gear box
Drive Shaft
Fills
Sigma fills
Counter flow cooling tower fill
Cross corrugated PVC fills
Splash fills
FRP GRATINGS
Cross flow cooling tower fills
V bar
PVC fills

Air intake mesh

Drift eleminator

Drift Eliminators, made out of rigid PVC, are designed to remove entrained particles from air steam efficiently, with minimum pressure drop, thereby reducing the fan power requirement when the air passes through the Drift Eliminator. Water droplets are separated from the air drift at the three direction change points on the drift eliminator. Blade drift eleminator

Cellular drift eleminator

Technical Data

Suggested Cooling Tower Application Counterflow Crossflow
Type Of Structure Cellular P
Maximum Face Velocity (m/sec) 4.5 4
Module Length 600 mm 600 - 3000 mm
Module Width 600 mm 1200 mm or as required
Module Depth 130 mm 100 mm
Distance Between Profiles 20 35
Directional changes for air flow 3 3
Maximum Continuous Temperature (C) 55 55

Nozzles

The performance of cooling tower greatly depends upon the water distribution over the fills.Nozzles distribute water evenly through a wide spray angle without any dry pockets. They are lightweight and reduce the frequency of clogging.

The Solid Cone Square Pattern (SCSP) nozzles produce a solid cone spray of water that is distributed in a square pattern onto the fills. These nozzles can be used on new/existing pipe, which may be of MS, PP, PVC or AC pipes.

These nozzles are made out of a basic body of ABS plastics and three different types of nylon inserts and turbulators. The turbulators and orifice when assembled with the ABS body generate three types of nozzles capable of discharging water flow rates ranging from 30 GPM to 120 GPM. Depending upon the selection, each nozzle covers an area of 2'X2' to 4'X4' of tower area. A water flow chart to determine the selection may be provided on request.

Cooling tower valves
Float valve
Butterfly valves
Flow control valves

Other Products :

Cooling Tower
Ducting
HVAC
Piping & Ducting
Fan Motor
Fan Guard
Motor frame ass'y
Fan Blade ass'y
Sprinkler pipe
Eliminator
Sprinkler head
Stand pipe
FRP casing
PVC Filling
Filling supporter
Casing supporter
Frame ass'y
Tension Device
Inlet louver
Automatic filler
Quick filler
Inlet
Water Sump
Water basin
Outlet
Fan
Ladder
Turn Buckle
Tension Bar
PVC Center Eliminator
Air Inlet Post
Upper Angle
Air Inlet Mesh
Slant Post
Make up Connection
Over Flow
 

 

 

 

 

Profile   |   Products   |   Services   |   Enquiry   |   Contact

© copyright 2012-2013.©Cooling Tower Fabricators Pvt. Ltd.All Rights Reserved.
 
Developed By Psoft Infotech